November 1998, Article 6

November 1998, Article 6

Comparison of Finite-Difference and SPICE Tools for Thermal Modeling of the Effects of Nonuniform Power Generation in High-Power CPUs

This paper describes a thermal study of junction temperature variation across the surface of a large CPU resulting from nonuniform power generation. Results from Flotherm finite-difference thermal analysis software were compared to results from a SPICE simulation. Both simulations provided results close to measured values. Each tool offered strengths and benefits in different areas.

by Jeffrey L. Deeney and C. Michael Ramsey


Article 6 - nov98a6.pdf


This article is available in Adobe Acrobat format (PDF). To view this article you need to have Acrobat Reader 2.0 or later installed on your system. The Acrobat reader is available free of charge in Unix, Dos, Windows and Macintosh formats. You can download the reader from Adobe Systems (www.adobe.com)